Calculation of Fluctuating water pressure impinging on roof of tank:Square Glassfiber Reinforced Plastic Water Tank

Calculation of Fluctuating water pressure impinging on roof of tank:Square Glassfiber Reinforced Plastic Water Tank

1Water level:hm-
2Breadth of FRP water tank:LmSquare Glassfiber Reinforced Plastic Water Tank
3Velocity Response Spectrum:Svm/sVelocity Response Spectrum for design
4Structural characteristic factor:Ds-
5Height of void:hsm-
6Unit mass of water:ρkg/m^3-
7Gravitational acceleration:gm/s^2-
8GraphPlot Input Data: , Figure:
You need to upgrade your Flash Player
:Export Graph Image.

Keyword・Reference・Remarks・History

LaTex

Keyword

Primary Natural Period of Sloshing,Square Glassfiber Reinforced Plastic Water Tank

Reference

[1]:社団法人強化プラスチック協会:『FRP水槽耐震設計基準(1996年版)』,pp.16-17

Remarks

・Water level:h
・Breadth of FRP Water Tank:L
・Velocity Response Spectrum for design:Sv
・Primary natural circular frequency of Sloshing:ωs(=2π/Ts)
・Primary Natural Period of Sloshing:Ts
・Structural characteristic factor:Ds
・Unit mass of water:ρ
・Making Equation Image is powered by CODECOGS

History

・2010/09/08:Upload