Calculation of Bearing capacity factors due to Internal friction angle

Calculation of Bearing capacity factors due to Internal friction angle

1Internal friction angle:φ°Max:40°
2GraphPlot Input Data:
3Number of gridlines of Graph x-axis, y-axis -
You need to upgrade your Flash Player
:Export Graph Image.

Keyword・Reference・Remarks・History

LaTex

Keyword

Bearing capacity factors,Internal friction angle,Prandtl's solution,Reissner's solution,Meyerhof's approximate solution

Reference

[1]:社団法人日本建築学会:『建築基礎構造設計指針 2001改訂』,pp.105-108.

Remarks

・Internal friction angle:φ
・Internal friction angle:Nq,Nc,Nr
・When input φ equals zero, Internal friction angle "Nc" is 5.1.
・Making Equation Image is powered by CODECOGS

History

・2011/03/04:Upload

Copyright©Asset Management Consulting Corporation All Rights Reserved.