Calculation of Alternate Floor Live Load Reduction by Building Code of Pakistan

Calculation of Alternate Floor Live Load Reduction by Building Code of Pakistan

1AI(m^2)m^2. 37(m^2)≦Ai-
2Use or occupancy -
3Member -
4Graph -
5Plot Input Data -
6Gridlines x-axis, y-axis :Number of gridlines of Graph-
You need to upgrade your Flash Player
:Export Graph Image.

Keyword・Reference・Remarks・History

LaTex

Keyword

Building Code of Pakistan,Alternate Floor Live Load Reduction,Reduced design live load,Influence area

Reference

[1]:Pakistan Engineering Council『Building Code of Pakistan BCP SP-2007』.pp.5-5 - 5-6.

Remarks

・AI:『influence area, in square meter (ft2). The influence area AI is four times the tributary area for a column, two times the tributary area for a beam, equal to the panel area for a two-way slab, and equal to the product of the span and the full flange width for a precast T-beam.』(Reference[1])
・L:『reduced design live load per square meter (ft2) of area supported by the member.』(Reference[1])
・Lo:『unreduced design live load per square meter (ft2) of area supported by the member』(Reference[1])
・『The reduced live load shall not be less than 50 percent of the unit live load Lo for members receiving load from one level only, nor less than 40 percent of the unit live load Lo for other members.』(Reference[1])